Area of application
OLE paper joint cover strips are ideal for filling joints in drywall construction with plasterboard or drywall in interior areas.
Preparation
Prepare the surface to be reinforced in accordance with VOB, Part C, DIN 18363, DIN 18350 or BFS data sheets. The substrate must be dry and dust-free. If necessary, apply a primer.
Processing
Fill the joint with a suitable levelling compound and insert OLE paper joint cover strips into the still damp levelling layer without creases or bubbles and press down firmly using a suitable smoothing tool. Then apply embedding material again to cover the joint strips and smooth down. Repeat this process if necessary.
Consumption
depending on joint size and depth
Storage
Store in a dry, cool and closed place.
Notes
Carry out further work in accordance with the respective manufacturer's instructions.